    Laser Damage Threshold Testing

    技術文章

    Laser Damage Threshold Testing

    Laser Damage Threshold (LDT), also known as Laser Induced Damage Threshold (LIDT), is one of the most important specifications to consider when integrating an optical component such as a mirror into a laser system. Using a laser in an application offers a variety of benefits to a standard light source, including monochromaticity, directionality, and coherence. Laser beams often contain high energies and are capable of damaging sensitive optical components. When integrating a laser and optical components into a system, it is crucial to understand the effects of laser beams on optical surfaces and how laser damage threshold is quantified for optical components.

     

    The type of damage induced to an optical component by a laser beam is dependent on the wavelength, pulse length, polarization, rep rate, and spatial characteristics among other factors. During exposure to a continuous wave (CW) laser, failure can occur due to laser energy absorption and thermal damage or melting of the substrate material or the optical coating. The damage caused by a short nanosecond laser pulses is typically due to dielectric breakdown of the material that results from exposure to the high electric fields in the laser beam. For pulse widths in between these two regimes or for high rep rate laser systems, laser induced damage may result from a combination of thermally induced damage and breakdown. For ultrashort pulses, about 10ps or less, nonlinear mechanisms such as multiphoton absorption and multiphoton ionization become important.

     

    Testing Laser Damage Threshold

    Laser-Induced Damage Threshold (LIDT) testing is a good method for quantifying the amount of electromagnetic radiation an optical component can withstand. There are a variety of different LDT tests. For example, Edmund Optics follows the ISO-11254 procedures and methods, which is the industry standard for determining the laser damage threshold of an optical component. Utilizing the ISO-11254 standard enables the fair comparison between optical components from different manufacturers.

     

    Edmund Optics' LDT testing is conducted by irradiating a number of test sites with a laser beam at different energy densities for pulsed lasers, or different power densities for CW lasers. The energy density or power density is incrementally increased at a minimum of ten sites at each increment. The process is repeated until damage is observed in of the irradiated sites. The LDT is the highest energy or power level at which no damage is observed in any of the irradiated sites. Inspection of the sites is done with a Nomarsky-type Differential Interference Contrast (DIC) microscope with 100X - 150X magnification. Visible damage is observed and the results are recorded using pass/fail criteria. Figure 1 is a typical damage probability plot of exposure sites as a function of laser pulse energy.

    Figure 1: Exposure Histogram of Laser Damage Threshold Probability versus Exposure Site

     

    In addition to uncoated optical components, optical coatings are also subject to damage from the presence of absorption sites and plasma burn. Figure 2 is a real-world image of coating failure due to a coating defect. For additional information on the importance of LDT testing on coatings, view The Complexities of High-Power Optical Coatings.

    Figure 2: Coating Failure from 73.3 J/cm2 Source due to Coating Defect

     

    Defining Laser Damage Threshold

    There are many variables that affect the Laser Damage Threshold (LDT) of an optical component. These variables can be separated into three categories: laser, substrate, and optical coating (Table 1).

    Variables that Affect LDT/LIDT

    Laser

    Substrate

    Coating

    Output Power

    Material

    Deposited Material

    Pulse duration

    Surface Quality

    Deposition Process

    Pulse Repetition Rate

    Cleanliness

    Pre-Coating Preparation and Cleaning

    Beam Profile

    Reactivity to the Environment

    Lot-to-Lot Control

    Beam Diameter (1/e2)

    Material Absorption

    Coating Design and Optimization

    Wavelength

    Material Homogeneity

    Protective Layers

    LDT is typically quantified by power or energy densities for CW and pulsed lasers, respectively. Power density is the power per cross-sectional beam area of the laser beam (typically W/cm2). Similarly, energy density is the energy per cross-sectional beam area of a specific pulse duration (typically given in J/cm2). Lasers are available with a multitude of different wavelengths and pulse durations, therefore, it is useful to be able to scale LDT data to help determine if an optical component is suitable for use with a given laser. As a general rule of thumb, the following equation can be used to roughly estimate LDT from given data, LDT(λ1,τ1), LDT(λ2,τ2). This approximation only holds when scaling over relatively small wavelength or timescale ranges, and can not be used to extrapolate e.g. from ns to fs pulses, or from UV to IR.

    In this equation τ1 is the laser pulse length and λ1 is the laser wavelength for the given LDT and τ2 is the laser pulse length and λ2 is the laser wavelength with unknown LDT. For example, the LDT for a mirror is 20 J/cm2 at 1064nm @ 20 ns. The LDT using the scaling rule above at 532nm and 10 ns pulse is 20 x (532/1064) x (10/20)½ or about 7 J/cm2. For longer pulses and high rep rate pulsed lasers it is also necessary to check the CW power density limit as well. The scaling equation is not applicable to ultra-short ps to fs pulsed lasers. When using “scaling” rules, safety factors of at least two times the calculated values should be applied to help ensure optical elements will not be damaged.

    聯系我們

    地址:江蘇省江陰市人民東路1091號1017室 傳真:0510-68836817 Email:sales@rympo.com
    24小時在線客服,為您服務!

    版權所有 © 2025 江陰韻翔光電技術有限公司 備案號:蘇ICP備16003332號-1 技術支持:化工儀器網 管理登陸 GoogleSitemap

    在線咨詢
    QQ客服
    QQ:17041053
    電話咨詢
    0510-68836815
    關注微信
    主站蜘蛛池模板: 亚洲精品第一国产综合精品| 97久久国产综合精品女不卡| 亚洲综合校园春色| 91精品婷婷国产综合久久| 亚洲高清中文字幕综合网| 久久桃花综合桃花七七网| 狠狠色丁香婷婷综合激情| 色综合67194| 色噜噜狠狠狠综合曰曰曰| 伊人久久综合精品无码AV专区| 综合五月激情五月开心婷婷| 亚洲伊人久久综合影院| 六月婷婷国产精品综合| 97久久国产综合精品女不卡 | 亚洲综合色在线观看亚洲| 国产亚洲综合久久系列| 综合五月激情二区视频| 亚洲综合在线观看视频| 国产亚洲综合色就色| 亚洲综合亚洲综合网成人| 色婷婷久久综合中文久久蜜桃 | 久久久久综合一本久道| 一本久久综合亚洲鲁鲁五月天| 亚洲综合色丁香麻豆| 激情综合婷婷丁香五月| 伊人久久综合谁合综合久久| 天天做天天爱天天综合网| 成人伊人青草久久综合网破解版| 亚洲色偷偷偷综合网| 亚洲私人无码综合久久网| 丁香婷婷激情综合俺也去 | 亚洲国产亚洲综合在线尤物| 激情五月激情综合网| 精品亚洲综合在线第一区| 久久综合给合综合久久| 久久久久久久尹人综合网亚洲| 伊人网综合在线视频| 亚洲综合久久综合激情久久| 亚洲 欧洲 日韩 综合在线| 色综合久久加勒比高清88| 伊人久久亚洲综合影院|